Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Infect Chemother ; 29(6): 586-591, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849098

RESUMO

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, a rapid and reliable point-of-care test is an essential tool for controlling the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In particular, an immunochromatography test (ICT) that uses saliva specimens for rapid antigen detection not only reduces the risk of secondary infections but also reduces the burden on medical personnel. METHODS: The newly developed salivary antigen test kit "Inspecter Kowa® SARS-CoV-2" is an ICT to which saliva specimens can be directly applied. We evaluated its usefulness in comparison with reverse transcription quantitative PCR (RT-qPCR) and the Espline® SARS-CoV-2 Kit for the detection of SARS-CoV-2 using nasopharyngeal swab specimens. In this study, 140 patients with suspected symptomatic COVID-19 who visited our hospital were enrolled, and nasopharyngeal swab and saliva specimens were collected after they consented to participate in the study. RESULTS: Inspector Kowa SARS-CoV-2 was positive in 45 of 61 (73.8%) saliva that were positive by RT-qPCR and the Espline® SARS-CoV-2 Kit was also positive in 56 of 60 (93.3%) Np swabs that were positive by RT-qPCR. Good antigen detection was achieved by ICT with saliva and nasopharyngeal swab specimens when viral load was ≥105 copies/mL, whereas detection sensitivity was low when viral load was <105 copies/mL, especially in saliva specimens. CONCLUSION: This ICT for the detection of SARS-CoV-2 salivary antigen is an attractive tool that does not require specialized equipment and allows patients to perform the entire process from sample collection to self-diagnose and to reduce the burden on medical care during a pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Manejo de Espécimes/métodos , Nasofaringe
2.
J Med Virol ; 94(1): 335-341, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34524695

RESUMO

Fully automated immunoassays for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies that are strongly correlated with neutralization antibodies (nAbs) are clinically important because they enable the assessment of humoral immunity after infection and vaccination. Access SARS-CoV-2 immunoglobulin M (IgM) and immunoglobulin G (IgG) II antibody tests are semi-quantitative, fully automated immunoassays that detect anti-receptor-binding domain (RBD) antibodies and might reflect nAb levels in coronavirus disease 2019 (COVID-19). However, no studies have investigated the clinical utility of these tests in association with nAbs to date. To evaluate the clinical utility of Access SARS-CoV-2 IgM and IgG II antibody tests and their correlation with the SARS-CoV-2 surrogate virus neutralization test (sVNT) that measures nAbs in patients with COVID-19, we analyzed 54 convalescent serum samples from COVID-19 patients and 89 serum samples from non-COVID-19 patients. The presence of anti-RBD antibodies was detected using Access SARS-CoV-2 IgM and IgG II antibody tests, while nAbs were measured by sVNT. The sensitivity and specificity of sVNT were 94.4% and 98.9%, respectively. There were strong positive correlations between the inhibition values of sVNT and the results of the Access SARS-CoV-2 IgM (R = 0.95, R2 = 0.90, p < 0.001) and IgG II antibody tests (R = 0.96, R2 = 0.92, p < 0.001). In terms of the presence of nAbs, the sensitivity and specificity were 98.1% and 98.9% in the IgM assay and 100.0% and 100.0% in the IgG II assay, respectively. The Access SARS-CoV-2 IgM and IgG II antibody tests showed high sensitivity and specificity for the detection of nAbs in COVID-19 patients and might be alternatives for measuring nAbs.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Imunoensaio/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Neutralização/métodos , Sensibilidade e Especificidade
3.
Int J Infect Dis ; 111: 68-75, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34407480

RESUMO

BACKGROUND: The cross-reactive antibody response against seasonal human coronaviruses (HCoVs) was evaluated according to disease severity in patients with COVID-19 in Japan. METHODS: In total, 194 paired serum samples collected from 97 patients with COVID-19 (mild, 35; severe, 62) were analyzed on admission and during convalescence. IgG antibodies against the nucleocapsid (N) and spike (S) proteins of SARS-CoV-2 and four seasonal HCoVs (HCoV-NL63, -229E, -OC43, and -HKU1) were detected by enzyme-linked immunosorbent assays. RESULTS: There was no difference in optical density (OD) values for seasonal HCoVs on admission between the severe and mild cases. In addition, a specific pattern of disease severity-associated OD values for HCoVs was not identified. Significant increases in OD values from admission to convalescence for HCoV-HKU1and -OC43 IgG-S, and for HCoV-NL63 and -229E IgG-N were observed in the severe cases. Significant differences were observed between the mild and severe cases for HCoV-HKU1 and -OC43 IgG-S OD values during convalescence. Correlations were found between the fold changes for HCoV-OC43 IgG-S OD values, and for SARS-CoV-2 IgG-S OD values, and C-reactive protein, lactate dehydrogenase, and lymphocyte levels. CONCLUSION: There was no association between the antibody titer for seasonal HCoVs in the early phase of COVID-19 and disease severity.


Assuntos
COVID-19 , Humanos , Imunidade Humoral , SARS-CoV-2 , Estações do Ano , Índice de Gravidade de Doença , Glicoproteína da Espícula de Coronavírus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...